Product Details:
Minimum Order Quantity | 1 Piece |
Weight | 35 KG |
Airflow | PM-10 (16.67 LPM), PM- 2.5 (16.67 LPM) |
Product Dimension | 430 x 320 x 930mm |
Power Source | MANUAL |
Voltage | 220 VOLT |
Metal Karatage | ALUMINIUM |
Usage Application | DUST MONITORING |
Particle Size: | Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor. |
Sampling rate: | Constant sampling rate of 1m3/hr unaffected by voltage fluctuation and filter choking maintained by critical orifice system. |
Filter Media: | Filter holder designed to accept any standard 47 mm diameter filter media. |
Sample Volume: | Fitting 2Nos. of Dry Gas meter records the total air volume sampled for PM10 & PM2.5. |
Power Requirement: | Single phase AC 220 Volts, 50 Hertz supply. Sampler unaffected by /- 10% fluctuation in supply voltage |
Additional Information:
Product Details:
Minimum Order Quantity | 1 Piece |
Usage/Application | USEPA |
Material | ALUMINIUM |
Brand | GREENTECH INSTRUMENT |
Automation Grade | Manual |
Power | 220 VOLT |
Accuracy | FSD 2% |
Battery Voltage | NA |
Color | Off White |
Ø PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA.
Ø The GTI-241 uses a brushless pump with a low noise.
Ø Easy Sampling PM10 and PM2.5 both in one time.
Ø Low sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels.
Ø Critical Orifice maintains constant sampling rate of 1m3/hour.
Ø Compact and portable for convenient field operation.
Ø This sampler suitable for measurement of PM10 and PM2.5 simultaneously
Ø PM10 & PM 2.5 Impactors of sampler are based on designs standardized by USEPA
Ø Critical orifice maintains constant sampling rate of 1m3/hr.
Ø Sampler can run continuously for 28 hrs monitoring.
Ø Pump assembly brushless and noiseless motor with low maintenance.
KEY SPECIFICATION:
Particle Size | :OmnOmni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor. |
Sampling rate | :Con Constant sampling rate for both PM 10/PM 2.5 has 1m3/hr uffected by voltage fluctuation and filter choking maintained by critical orifice system. |
Filter Media | :Filte Filter holder designed to accept any standard 47 mm diameter filter. |
Sample Volume | :2 No2 Nos. Dry Gas meter records the total air volume sampled through PM 10 and PM 2.5 |
Power Requirement:
Gaseous Flow rate : | Single phase AC 220 Volts, 50 Hertz supply. Sampler unaffected by +/- 10% fluctuation in supply voltage 0.3 to 3 LPM+ 2% accuracy on span |
Flow control : Four inlets and one outlet with built within needle valves for Flow control.
Sampling train : 2 nos. of 35 ml borosilicate midget glass Impinger
Product Details:
Minimum Order Quantity | 1 Piece |
Weight | 38 kg |
Airflow | 16.67 +38 lpm + Gaseous |
Voltage | 220 Volt |
Usage Application | USEPA |
We come with a highly advanced Combo Dust Sampler that is known for its sturdy and improved cabinet design. These Combo Dust Sampler have profound uses in analysis of particulates level in the air, owing to their high efficiency and combined functionality of sampling variable particle sizes. The design and fabrication of these products are accomplished by diligent expertise with the effective utilization of savant-grade technology. Furthermore, the supply is done in tamper-proof packaging at market leading rates.
Features:
Ø TECHNICAL SPECIFICATIONS:
Ø Flow Rate Pm10 : 2.3m3 /hr (Constant Flow Maintained with the help of critical orifice )
Ø Pm2.5 : 1.0m3/hr (Constant Flow Maintained with the help of critical orifice )
Ø Particle Size :Particles of 10 microns and below collected on standard glass micro fiber
Ø filter paper of 47mm diameter fitted below single stage impactor. While particles of 2.5 microns are collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS impactor of two stage impactor.
Ø Pm10 impactor : Single stage matching to European Design (according to EN12341)
Ø Pm2.5 Impactor : Two stage as per USEPA Published Designs(Federal Register 40 CFR part 50)
Ø Flow Record: Independent Flow Totalizer for Pm10 & Pm2.5 streams to record volume sucked through filters accurately.
Ø Cabinet: Single modular, corrosion free, lockable & easy to transport.
Ø Operation :Up-to 28 hours continuously
Ø Automatic Sampling :A digital timer is provided to automate the operation of sampler
Ø Time :0 to 9999.99 hrs recorded on a Digital Time Totalizer
Ø Power Requirement :Nominal 220V, Single Phase, 50Hz AC mains supply,400watts
Additional Information: