Greentech Instruments
Greentech Instruments
Okhla Industrial Estate, New Delhi, Delhi
GST No. 07DQBPS7249F2ZI
TrustSEAL Verified
Call 0804896880486% Response Rate
SEND EMAIL

PM 10 & 2.5 SAMPLER

Pioneers in the industry, we offer pm 10, pm 2.5, spm, gaseous sampler, air pollution monitoring instruments, multi dust sampler (gti-241 a) and combined sampler (gti-241 digital) from India.

PM 10, PM 2.5, SPM, Gaseous Sampler

PM 10, PM 2.5,  SPM, Gaseous Sampler
  • PM 10, PM 2.5,  SPM, Gaseous Sampler
  • PM 10, PM 2.5,  SPM, Gaseous Sampler
  • PM 10, PM 2.5,  SPM, Gaseous Sampler
Get Best Quote
Approx. Price: Rs 80,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Weight48 KG
Airflow0.9 - 1.4 m3 /min free flow & 16.67 lPM
Product Dimension430 x 320 x 930mm
Power SourceMANUAL
Voltage220 Volt
Usage ApplicationPM 10 & SPM

We are widely reckoned in the market as notable manufacturer and supplier of Respirable Dust Sampler. Widely used in accurate analysis of dust in air, these are known for high sturdiness and efficiency. Owing to there manufacturing being done with the aid of high-grade technology, these samplers are supplied by us in various stipulations. In addition to this, we make the prompt delivery of products in durable packaging at affordable price tags.

Features:

  • Superb functionality
  • High robustness
  • Easy to use

Specifications :

 

Flow Rate : - 0.9 – 1.4 m3 /min free flow

Particle Size : - Particles of 10 microns & below collected on Filter Paper holder. SPM

bigger than 10 microns Collected in a separate sampling bottle under the

cyclone.

Sampling Time : - 28 hours (maximum)

Sampling Time Record: - 0 to 9999.99 hrs. Recorded on a Time Totalizer.

Automatic Sampling :- 24 hrs programmable timer to automatically shut off the system after pre set

time interval.

Power Requirement : - Nominal 220 V, Single Phase, 50Hz AC mains supply.

Size & Weight : - 430 x 320 x 930mm.38Kg

Gaseous Flow Rate :- 0.3 lpm measured using plastic body flow meter.

Sampling Train : - Four inlet one outlet manifold with built in needle valves for flow control of each inlet.

Absorbers : - 4Nos. Of 35 ml. Glass impingers.

Size & Weight : - 240 x 125 x 360 Inch.38Kg

Ice Trey : - fiber

voltage stabilizer : Power Cut Minimum & Maximum (170 to 240 )

Particle Size: Omni-directional air inlet with PM 10 separation through an impactor Followed by PM 2.5 separations through a WINS Impactor.

Sampling rate:Constant sampling rate of 1m3/hr unaffected by voltage fluctuation And Filter choking maintained by critical orifice system.

Filter Media:Filter holder designed to accept any standard 47 mm diameter filter Media.

  • Sample Volume: Dry Gas meter records the total air volume sampled.
  • Power Requirement: Single phase AC 220 Volts, 50 Hertz supply. Sampler Unaffected by
  • +/- 10% fluctuation in supply voltage.
Request
Callback


Additional Information:

  • Delivery Time: As Per Req
Yes! I am Interested

Air Pollution Monitoring Instruments

Air Pollution Monitoring Instruments
  • Air Pollution Monitoring Instruments
  • Air Pollution Monitoring Instruments
  • Air Pollution Monitoring Instruments
Get Best Quote
Approx. Price: Rs 55,000 / EachGet Latest Price

Product Details:

Minimum Order Quantity1 Each
MaterialMild Steel
Automation GradeFully Automatic
COMBO SAMPLER(38 LPM)(16.67 LPM)
DeliveryPAN India
Country of OriginMade in India

We have achieved remarkable success in this domain by manufacturing and supplying best in class Air Pollution Monitoring Instruments. These instruments due to their reliable capability in providing accurate results for prolong time duration have made them much useful in analysis and monitoring of particulates in the air. We have with us wide stipulations of these instruments for supply to customers as per their requirements.

Features:
  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA
  • Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature
  • Lower sampling rate of 1m3/hr reduces filter choking even in areas having high FPM levels
  • Critical Orifice maintains constant sampling rate of 1 m3/hour
  • Sampler can run continuously 28 hrs monitoring
  • Can be measure PM10 or PM2.5 at a time
  • Calibration Certificate for each instrument shall be provided with instruments
  • Compact and portable
Request
Callback


Additional Information:

  • Item Code: GTI-261
  • Production Capacity: 500
  • Delivery Time: AS PER REQUIRMENT
  • Packaging Details: CARD BOX
Yes! I am Interested

Multi Dust Sampler (GTI-241 A)

Multi Dust Sampler (GTI-241 A)
  • Multi Dust Sampler (GTI-241 A)
  • Multi Dust Sampler (GTI-241 A)
  • Multi Dust Sampler (GTI-241 A)
  • Multi Dust Sampler (GTI-241 A)
Get Best Quote
Approx. Price: Rs 60,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Weight30 kg
Airflow16.67 & 16.67 Lpm
Power SourceMANUAL
Voltage220 Volt
Usage ApplicationPM 10 & PM 2.5

Combined Sampler GTI- 241A

  • FEATURES
  • PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA.
  • The GTI-241 uses a brushless pump with a low noise.
  • Easy Sampling PM10 and PM2.5 both in one time.
  • Low sampling rate of 1m3/hr reduces filter choking even in areas having high FPM
  • levels.
  • Critical Orifice maintains constant sampling rate of 1m3/hour.
  • Compact and portable for convenient field operation.
  • This sampler suitable for measurement of PM10 and PM2.5 simultaneously
  • PM10 PM 2.5 Impactors of sampler are based on designs standardized by USEPA
  • Critical orifice maintains constant sampling rate of 1m3/hr.
  • Sampler can run continuously for 28 hrs monitoring.
  • Pump assembly brushless and noiseless motor with low maintenance.

KEY SPECIFICATION

Particle Size

OmnOmni-directional air inlet with PM10separation through an impactor

followed by PM 2.5 separation through a WINS Impactor.

Sampling rate

Con Constant sampling rate for both PM 10/PM 2.5 has 1m3/hr unaffected by

voltage fluctuation and filter choking maintained by critical orifice system.

Filter Media

Filte Filter holder designed to accept any standard 47 mm diameter filter media.

Sample Volume

2 No2 Nos. Dry Gas meter records the total air volume sampled through PM 10 and PM 2.5

Power Requirement

Single phase AC 220 Volts, 50 Hertz supply. Sampler unaffected by +/- 10% fluctuation in supply voltage.

Gaseous Flow Rate - 0.3 lpm measured using plastic body flow meter.

Sampling Train - Four inlet one outlet manifold with built in needle valves for flow control of each inlet.

Absorbers - 2Nos. Of 35 ml. Glass impingers.

Size Weight - 240 x 125 x 360 MM.38Kg

Ice Trey - fiber

Request
Callback


Additional Information:

  • Production Capacity: 200
  • Delivery Time: As Per Req
Yes! I am Interested

Combined Sampler (GTI-241 DIGITAL)

Combined Sampler (GTI-241 DIGITAL)
  • Combined Sampler (GTI-241 DIGITAL)
  • Combined Sampler (GTI-241 DIGITAL)
  • Combined Sampler (GTI-241 DIGITAL)
Get Best Quote
Approx. Price: Rs 95,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Weight20 Kg
Airflow1 Meter Cu./16.67 LPM
Product Dimension490 x 350 x 630
Power SourceElectronic
Frequency50
Voltage220 Volt
Energy Consumption.5
Metal KaratageAluminum
Usage ApplicationPM 10 & PM 2.5 Dust sampler
Country of OriginMade in India

This sampler is suitable for PM 10 & PM 2.5 monitoring
 Simultaneously both the parameter can be monitored at a time.
Special features:
 PM 10 and PM 2.5 Impactors of sampler based on designs standardized by USEPA.
 The GTI-241 Digital uses a brushless pump with a low noise.
 Auto shut off if flow rate drops significantly below 1 m3/hr.
 Microcontroller based data logger records Air Temp., Filter Temp. and Flow rate.  Windows based software for downloading data.  Pump Assembly in separate cabinet to prevent loss of volatile fraction and improve portability.
 Special imported oil-free brushless vacuum pump that is practically noiseless
 Size Selective inlets: Omni-directional air inlet with PM 10 separation through an impactor followed by PM 2.5 separation through a WINS Impactor
 Flow Rate:1 m3/hr controlled by mass flow controller  Vacuum Pump: Oil Free, non-pulsating pump driven by induction motor for stable flow rate
 Power requirement: Nominal 220 V, Single Phase, 50Hz AC mains supply. For proper operation and safety a good earth connection is mandatory
 Filter Media: Filter holder designed to accept any standard 47 mm & 46.2 mm diameter filter media
 Elapsed time indicator: Real Time clock records the operating time for each sample
 Flow recorder: Digital Microcontroller based system records flow rate, volume of air sampled, air temperature and filter temperature in non-volatile flash memory.   
Request
Callback


Additional Information:

  • Production Capacity: 50
  • Delivery Time: As Per Order
  • Packaging Details: Card Box
Yes! I am Interested
X

Explore More Products

View All Products




Reach Us
Sanjay Kumar (Proprietor)
Greentech Instruments
First Floor, B-91, Okhla Industrial Phase 1 Road, Okhla Industrial Estate Phase 1
New Delhi - 110020, Delhi, India


Call Us


Send E-mail